KILOWATTLAMPS
Home › UV exposure lamps › ORC HHL 2000 / C-FS

ORC HHL 2000 / C-FS — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 377 mm, undoped mercury (Hg). Also listed as Theimer TRQH 037072, Amba AM 317 X and 2 more part numbers.

PowerNot published — read it from the lamp label
DopingUndoped mercury (Hg)
Overall length (mm)377 (US distributor catalogue)
Doping / spectrumHg (undoped mercury)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the ORC HHL 2000 / C-FS?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
ORCHHL 2000 / C-FS
TheimerTRQH 037072 · TQH 037072
AmbaAM 317 X · AM 1226 X

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

ORC HHM 3000/E-FS · 375 mmORC HSL 3500/F-FS · 375 mmTheimer TR 3108 · 385 mmTheimer TR 3108 N · 391 mmORC HSL 3500FOS · 350 mmORC H8400L/A-N · 440 mmORC HHL 1500BOS · 300 mmUshio MHL 5000-5 · 280 mm

Frequently asked

Which part numbers are listed for the same lamp as the ORC HHL 2000 / C-FS?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 5 part numbers: ORC HHL 2000 / C-FS, Theimer TRQH 037072, Amba AM 317 X, Amba AM 1226 X, Theimer TQH 037072. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the ORC HHL 2000 / C-FS?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote