KILOWATTLAMPS
Home › UV exposure lamps › Theimer TH 5020

Theimer TH 5020 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 249 mm, gallium-doped (Ga). Also listed as Sack 200 216 OZ, Primarc 45000802 and 5 more part numbers.

Power5,000 W
DopingGallium-doped (Ga)
Overall length (mm)249 (US distributor catalogue); 245mm (Alpha-Cure Theimer TH5020); 244mm (Alpha-Cure Amba AM614X)
Arc / lighted length (mm)155mm (Alpha-Cure Theimer TH5020); 156mm (Alpha-Cure Amba AM614X)
Tube diameter (mm)28mm (Alpha-Cure Theimer TH5020); 28mm (Alpha-Cure Amba AM614X)
Base / connectionPinch seal (Alpha-Cure Theimer TH5020); Pinch seal (Alpha-Cure Amba AM614X)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TH 5020?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTH 5020
Sack200 216 OZ
Primarc45000802
KuehnastJGMH 5020-0
AmbaAM614X
HeraeusRQ 6138 Z1 KC
PhilipsHPM 4020
Dr. FischerHPM 4020

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL-5020 · 247 mmUshio MHL-5020S · 247 mmTheimer TR 3500 A · 245 mmTheimer TR 2060 · 245 mmTheimer TH 5490 · 254 mmTheimer TR 4110 · 255 mmUshio MHL 4000/U2 · 241 mmTheimer TR 4120 · 240 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TH 5020?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 8 part numbers: Theimer TH 5020, Sack 200 216 OZ, Primarc 45000802, Kuehnast JGMH 5020-0, Amba AM614X, Heraeus RQ 6138 Z1 KC, Philips HPM 4020, Dr. Fischer HPM 4020. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TH 5020?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote