KILOWATTLAMPS
Home › UV exposure lamps › Theimer TR 4010

Theimer TR 4010 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 200 mm, gallium-doped (Ga). Also listed as Theimer TH 4010, Heraeus 56001247 and 13 more part numbers.

Power2,990 W
DopingGallium-doped (Ga)
Overall length (mm)200 (US distributor catalogue); 200mm (Alpha-Cure Heraeus Q4137Z1); 200mm (Alpha-Cure Theimer TH4010)
Arc / lighted length (mm)100mm (Alpha-Cure Heraeus Q4137Z1); 100mm (Alpha-Cure Theimer TH4010)
Tube diameter (mm)32mm (Alpha-Cure Heraeus Q4137Z1); 32mm (Alpha-Cure Theimer TH4010)
Base / connectionPinch seal (Alpha-Cure Heraeus Q4137Z1); Pinch seal (Alpha-Cure Theimer TH4010)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TR 4010?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTR 4010 · TH 4010
Heraeus56001247 · 45006056 · Q 4137 Z1 · Q 4136 Z1 · AM 606 X
Danagraf A/SPD 295
HelioprintHE+71569 · MO 36.1
PhilipsHPM 30 · HPM 4010
SylvaniaMO 36
KuehnastJGMH 5082-0
Dr. FischerHPM 4010
AmbaAM 606 X

Equipment this lamp is listed for

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 2130 · 200 mmNuArc KT 19 · 202 mmTheimer TR 3800 H · 197 mmTheimer TR 4080 A · 205 mmTheimer TR 3060 · 195 mmUshio MHL 17 · 190 mmTheimer TR 3020 · 190 mmUshio MHL 6020 S · 210 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TR 4010?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 16 part numbers: Theimer TR 4010, Theimer TH 4010, Heraeus 56001247, Heraeus 45006056, Danagraf A/S PD 295, Helioprint HE+71569, Helioprint MO 36.1, Philips HPM 30, Heraeus Q 4137 Z1, Heraeus Q 4136 Z1, Sylvania MO 36, Kuehnast JGMH 5082-0, Dr. Fischer HPM 4010, Philips HPM 4010, Heraeus AM 606 X, Amba AM 606 X. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TR 4010?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote