KILOWATTLAMPS
Home › Mercury short-arc lamps › HBO 5000 W/C

OSRAM HBO 5000 W/C — mercury short-arc lamp, 5 kW

LCD panel aligners

Rated power5000 W
Lamp voltage56 V
Lamp current77 A
Arc gap (cold)5 mm
Overall length352 / 328 mm
Bulb diameter82 mm
Base / connectioncathode SFc 33.5-12/50; anode SFc 33.5-24/33 with M10 cable
Burn positionvertical, anode up; forced base cooling
Rated life500 h
ApplicationLCD panel aligners
–+cathodeanodeOverall length A = 352 mmLight centre length BBulb ØD = 82 mmArc gap G = 5 mm
OSRAM HBO 5000 W/C — Schematic, not to scale. Dimensions shown are the published values for this part number. The light-centre reference end differs between lamp types; confirm against the original drawing.

Need a HBO 5000 W/C replacement?

Send the part number and your exposure tool model. We check power, base, dimensions and burn position against the original and quote within 24 hours.

Quote form

Equipment this lamp is published for

Canon MPA-5000

Other mercury lamps of similar power

OSRAM HBO 4300 W/NOSRAM HBO 5000 W/HKOSRAM HBO 5000 W/MFOSRAM HBO 5000 W/SOSRAM HBO 5000 W/TAOSRAM HBO 5001 W/FAdvanced Radiation HSA-5000 TAM

Frequently asked

What is the OSRAM HBO 5000 W/C used for?

It is a 5000 W super-high-pressure mercury short-arc lamp used for lcd panel aligners, published for Canon MPA-5000.

Can you supply a replacement for the OSRAM HBO 5000 W/C?

Send us the part number, a photo of the lamp label and your exposure tool model. We match power, voltage, current, base, cable, overall length and light-centre length against the original before we quote, and state warranty hours on the quote.

How often should an exposure mercury lamp be replaced?

Typical rated life for high-power lithography and exposure lamps is 500 to 2,250 hours depending on type. UV output falls and arc stability degrades with age, which shows up as longer exposure times and non-uniformity, so plan replacement at rated life.

Safety: mercury short-arc lamps are under high pressure and contain mercury. Handle with face shield and gloves, keep the protective cover on until installed, and return used lamps for mercury recycling.

Specifications as published in: OSRAM HBO microlithography technical guide, 1999/2000 edition (source). Older types may be discontinued by the manufacturer; data is given for identification only. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with OSRAM.

WhatsApp quote