KILOWATTLAMPS
Home › UV exposure lamps › Amergraph V 28 12.00 SE

Amergraph V 28 12.00 SE — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 147 mm, iron-doped (Fe). Also listed as Theimer TR 2357, NuArc UPM 1000 and 1 more part numbers.

PowerNot published — read it from the lamp label
DopingIron-doped (Fe)
Overall length (mm)147 (US distributor catalogue)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Amergraph V 28 12.00 SE?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
AmergraphV 28 12.00 SE
TheimerTR 2357 · TH 2357
NuArcUPM 1000

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

NuArc PD 27 · 146 mmTheimer TRS 4027 · 145 mmTheimer TRS 4027 O · 145 mmUshio MHL 3005 · 132 mmTheimer TRS 3007 · 132 mmTheimer TRS 2117 · 132 mmUshio MHL 1403 · 175 mmNuArc R 6074 · 178 mm

Frequently asked

Which part numbers are listed for the same lamp as the Amergraph V 28 12.00 SE?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 4 part numbers: Amergraph V 28 12.00 SE, Theimer TR 2357, NuArc UPM 1000, Theimer TH 2357. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Amergraph V 28 12.00 SE?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote