KILOWATTLAMPS
Home › UV exposure lamps › Ushio MHL 3005

Ushio MHL 3005 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 132 mm, iron-doped (Fe). Also listed as Theimer TR 3007, Heraeus Q 2128 Z4 and 16 more part numbers.

Power3,000 W (published figures differ between sources — confirm on the label)
DopingIron-doped (Fe)
Overall length (mm)132 (US distributor catalogue); 133mm (Alpha-Cure Amba AM597X)
Arc / lighted length (mm)39mm (Alpha-Cure Amba AM597X)
Tube diameter (mm)28mm (Alpha-Cure Amba AM597X)
Base / connectionPinch seal (Alpha-Cure Amba AM597X)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 3005?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 3005
TheimerTR 3007 · TH 3007
HeraeusQ 2128 Z4 · 56069992 · RQ 2128 Z4 · 45006051 · RQ 2130 Z4
Klimsch659 7380 · 3000 W HF
BLVMHL 3005
AmbaAM 597 X
SylvaniaMO 58
Sack200 413
PhilipsHPA 2030 R · HPA 2010 R
Kuehnast3000-7
Eskofot410-219-000 · 410-214-000

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TRS 3007 · 132 mmTheimer TRS 2117 · 132 mmTheimer TRS 4027 · 145 mmTheimer TRS 4027 O · 145 mmNuArc PD 27 · 146 mmAmergraph V 28 12.00 SE · 147 mmUshio MHL 1403 · 175 mmNuArc R 6074 · 178 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 3005?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 19 part numbers: Ushio MHL 3005, Theimer TR 3007, Heraeus Q 2128 Z4, Klimsch 659 7380, Klimsch 3000 W HF, BLV MHL 3005, Amba AM 597 X, Theimer TH 3007, Sylvania MO 58, Sack 200 413, Philips HPA 2030 R, Philips HPA 2010 R, Kuehnast 3000-7, Heraeus 56069992, Heraeus RQ 2128 Z4, Heraeus 45006051, Heraeus RQ 2130 Z4, Eskofot 410-219-000, Eskofot 410-214-000. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 3005?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote