KILOWATTLAMPS
Home › UV exposure lamps › NuArc PD-27

NuArc PD-27 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 146 mm, undoped mercury (Hg). Also listed as NuArc 3140, NuArc MSP 3140 and 10 more part numbers.

PowerNot published — read it from the lamp label
DopingUndoped mercury (Hg)
Overall length (mm)146 (US distributor catalogue)
Doping / spectrumHg (undoped mercury)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the NuArc PD-27?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
NuArcPD-27 · 3140 · MSP 3140 · PD-41
M&R1044026 · PD41
CaprockPD-41
Worldwide005.0211
Light TechLET 005.0211
Theimer804609 · TRQ 014012 · TQ 014012
InterlightWW-3QZ7-1

Equipment this lamp is listed for

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 1198 · 162 mmAmergraph 10048 HG · 175 mmUshio MHL 15 · 205 mmORC SMX 8000 · 245 mmColight CHM 5000 · 260 mmUshio MHL 5000-5 · 280 mmORC HHL 1500BOS · 300 mmORC HSL 3500FOS · 350 mm

Frequently asked

Which part numbers are listed for the same lamp as the NuArc PD-27?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 13 part numbers: NuArc PD-27, NuArc 3140, NuArc MSP 3140, NuArc PD-41, M&R 1044026, Caprock PD-41, M&R PD41, Worldwide 005.0211, Light Tech LET 005.0211, Theimer 804609, Theimer TRQ 014012, Theimer TQ 014012, Interlight WW-3QZ7-1. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the NuArc PD-27?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote