Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 205 mm, undoped mercury (Hg). Also listed as Ushio 5000075, Sylvania MO38 and 29 more part numbers.
Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.
The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.
| Brand | Part number(s) |
|---|---|
| Ushio | MHL 15 · 5000075 |
| Sylvania | MO38 · M122.7 · M091 · M038 |
| Starna | STR2130-0 |
| Parker | PLM 15 |
| Kloter | CL 3000 |
| Heraeus | RQ 2136 · Q 2137 Z1 · Q 2737 Z11 · Q 2127 Z11 |
| Genesis | Q2137 Z11 |
| Delta | MHR/5/G |
| BLV | MHL 15 |
| Bluetec | 91-7484 |
| Theimer | TH 2030 · TR 2030 · TR 2160 · TH 2160 |
| Cure UV | 191130 |
| Beltron | TH 2030 · 28.054 |
| Philips | 928072305102 · HPM 15 DF B1/4 · HPM 15 |
| Dr. Fischer | 928072305102 · HPM 15 DF B1/4 · HPM 15 |
| Kuehnast | GMHO 2030-0 |
| Amba | AM 571 X |
Shown for navigation only — a lamp only fits if length, base and doping all match your unit.
In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 32 part numbers: Ushio MHL 15, Ushio 5000075, Sylvania MO38, Sylvania M122.7, Sylvania M091, Starna STR2130-0, Parker PLM 15, Kloter CL 3000, Heraeus RQ 2136, Heraeus Q 2137 Z1, Genesis Q2137 Z11, Delta MHR/5/G, BLV MHL 15, Bluetec 91-7484, Theimer TH 2030, Theimer TR 2030, Theimer TR 2160, Cure UV 191130, Heraeus Q 2737 Z11, Beltron TH 2030, Philips 928072305102, Dr. Fischer 928072305102, Dr. Fischer HPM 15 DF B1/4, Philips HPM 15 DF B1/4, Beltron 28.054, Kuehnast GMHO 2030-0, Sylvania M038, Theimer TH 2160, Amba AM 571 X, Heraeus Q 2127 Z11, Philips HPM 15, Dr. Fischer HPM 15. Confirm the length, base and doping of the lamp in your unit before ordering.
Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.
The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.
Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.