Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 280 mm, iron-doped (Fe). Also listed as Theimer THO 5017 C, Interlight WW-0SKL-3 and 3 more part numbers.

PowerNot published — read it from the lamp label
DopingIron-doped (Fe)
Overall length (mm)280 (US distributor catalogue)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TRO 5017 C?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTRO 5017 C · THO 5017 C
InterlightWW-0SKL-3
Addalux1406-07 with wires
Burgess754-18017 L · 754-18017 A

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL 5000-7 · 280 mmTheimer TRO 4097 B · 280 mmTheimer TR 3037 · 270 mmTheimer TR 8127 A · 252 mmTheimer TR 8217 · 248 mmUshio MHL 5027 · 247 mmTheimer TRS 5027 · 247 mmTheimer TR 5067 · 247 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TRO 5017 C?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 6 part numbers: Theimer TRO 5017 C, Theimer THO 5017 C, Interlight WW-0SKL-3, Addalux 1406-07 with wires, Burgess 754-18017 L, Burgess 754-18017 A. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TRO 5017 C?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.