KILOWATTLAMPS
Home › UV exposure lamps › Theimer TRS 5027

Theimer TRS 5027 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 247 mm, iron-doped (Fe). Also listed as Theimer 822597, Theimer THS 5027 and 10 more part numbers.

Power5,000 W (published figures differ between sources — confirm on the label)
DopingIron-doped (Fe)
Overall length (mm)247 (US distributor catalogue); 240mm MOL (Ushio); 247mm (Alpha-Cure Theimer THS 5027)
Arc / lighted length (mm)154mm lighted length (Ushio); 156mm (Alpha-Cure Theimer THS 5027)
Tube diameter (mm)28mm (Ushio); 28mm (Alpha-Cure Theimer THS 5027)
Base / connectionCeramic/THS base, AMP Connector contact (Ushio); Pinch seal (Alpha-Cure Theimer THS 5027)
Doping / spectrumFe (iron-doped); Ushio: 300-450nm Multi-Spectrum
Rated life (h)600 (US distributor catalogue typical/warranty); 500 average (Ushio)

Need a replacement for the Theimer TRS 5027?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTRS 5027 · 822597 · THS 5027
Heraeus45006075 · RQ 6136 Z4 KC · 45002214 · RQ 6139 Z4 KC
AmbaAM 617 X/S
BLV25560441
Starna50207 S
Ushio5000129
SylvaniaMO 69.2
Kuehnast5020-7S

Equipment this lamp is listed for

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL 5027 · 247 mmTheimer TR 5067 · 247 mmTheimer TR 8217 · 248 mmTheimer TR 4100 O · 246 mmTheimer TH 5717 H · 245 mmTheimer TR 8127 A · 252 mmAmergraph 10265 · 240 mmUshio MHL-153LY · 240 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TRS 5027?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 13 part numbers: Theimer TRS 5027, Theimer 822597, Theimer THS 5027, Heraeus 45006075, Heraeus RQ 6136 Z4 KC, Heraeus 45002214, Amba AM 617 X/S, BLV 25560441, Heraeus RQ 6139 Z4 KC, Starna 50207 S, Ushio 5000129, Sylvania MO 69.2, Kuehnast 5020-7S. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TRS 5027?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote