Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 230 mm, iron-doped (Fe). Also listed as Ushio 25410141, Ushio 5000112 and 21 more part numbers.
Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.
The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.
| Brand | Part number(s) |
|---|---|
| Ushio | MHL 4007 · 25410141 · 5000112 |
| Heraeus | 56069684 · 45006055 · Q 5528 Z4 · Q 5529 Z4 |
| Theimer | TH 4007 · TR 4007 |
| Kuehnast | 4000-7 |
| Cure UV | 191161 |
| Sylvania | MO 61 · MO 33 · 0500FST/610 · MO 54 |
| Staub | Ultra 5000 Poly · PC 130 FE · PC 004 |
| Sixt | HL 5000 FE |
| Sack | 200 715 · 200 415 UL |
| Klimsch | 659 7390 |
| Bacher | 56069684 |
| Amba | AM 605 X |
Shown for navigation only — a lamp only fits if length, base and doping all match your unit.
In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 24 part numbers: Ushio MHL 4007, Ushio 25410141, Ushio 5000112, Heraeus 56069684, Heraeus 45006055, Theimer TH 4007, Theimer TR 4007, Kuehnast 4000-7, Cure UV 191161, Sylvania MO 61, Sylvania MO 33, Sylvania 0500FST/610, Staub Ultra 5000 Poly, Staub PC 130 FE, Staub PC 004, Sixt HL 5000 FE, Sack 200 715, Sack 200 415 UL, Klimsch 659 7390, Heraeus Q 5528 Z4, Heraeus Q 5529 Z4, Bacher 56069684, Amba AM 605 X, Sylvania MO 54. Confirm the length, base and doping of the lamp in your unit before ordering.
Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.
The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.
Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.