Ushio MHL-5000/4 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 280 mm, gallium-doped (Ga). Also listed as Ushio 5000118, BLV 253591241 and 14 more part numbers.

Power5,000 W (published figures differ between sources — confirm on the label)
DopingGallium-doped (Ga)
Overall length (mm)280 (US distributor catalogue); 281mm MOL (Ushio); 280mm (Alpha-Cure Amba AM529X); 278mm (Alpha-Cure BLV MHL5000/4)
Arc / lighted length (mm)175mm lighted length (Ushio); 178mm (Alpha-Cure Amba AM529X); 166mm (Alpha-Cure BLV MHL5000/4)
Tube diameter (mm)25mm (Ushio); 26mm (Alpha-Cure Amba AM529X); 28mm (Alpha-Cure BLV MHL5000/4)
Base / connectionMetal 14.3mm base, Metal contact (Ushio); Pinch seal (Alpha-Cure Amba AM529X); Pinch seal (Alpha-Cure BLV MHL5000/4)
Doping / spectrumGa (gallium-doped); Ushio: 400-450nm Diazo
Rated life (h)600 (US distributor catalogue typical/warranty); 500 average (Ushio)

Need a replacement for the Ushio MHL-5000/4?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL-5000/4 · 5000118
BLV253591241 · MHL-5000/4
Kuehnast5010-0 OZ
TheimerTRO 5010 · THO 5010
SDLPAGA 5000/4
SylvaniaMO 45 · MP 5000 T8
StarnaSTR5010-0
AmbaAM 529 X
HeraeusQ 5846 Z1
HanoviaHF502C02
PhilipsHPM 25 B
Burgess754-18015
Addalux1406-04

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TRHO 5590 · 280 mmTechnigraf UK 936 · 280 mmTheimer TR 4090 B · 280 mmTheimer TRO 4090 · 280 mmORC AKP 5500 S · 280 mmUshio GL-50201BF · 280 mmTheimer TR 5140 · 281 mmTheimer TR 3250 H · 273 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL-5000/4?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 17 part numbers: Ushio MHL-5000/4, Ushio 5000118, BLV 253591241, Kuehnast 5010-0 OZ, Theimer TRO 5010, SDL PAGA 5000/4, Sylvania MO 45, Starna STR5010-0, Amba AM 529 X, BLV MHL-5000/4, Heraeus Q 5846 Z1, Hanovia HF502C02, Sylvania MP 5000 T8, Philips HPM 25 B, Burgess 754-18015, Addalux 1406-04, Theimer THO 5010. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL-5000/4?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote