KILOWATTLAMPS
Home › UV exposure lamps › Amergraph MP3000T8/6J

Amergraph MP3000T8/6J — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 240 mm, gallium-doped (Ga). Also listed as Theimer TR 3900, Sylvania MP 3000 T8 and 7 more part numbers.

Power2,960 W
DopingGallium-doped (Ga)
Overall length (mm)240 (US distributor catalogue); 225mm (Alpha-Cure BLV MHL3000/2)
Arc / lighted length (mm)137mm (Alpha-Cure BLV MHL3000/2)
Tube diameter (mm)28mm (Alpha-Cure BLV MHL3000/2)
Base / connectionPinch seal (Alpha-Cure BLV MHL3000/2)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Amergraph MP3000T8/6J?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
AmergraphMP3000T8/6J
TheimerTR 3900 · TH 3900
SylvaniaMP 3000 T8
UshioMHL 3000/2
BLVMHL 3000/2
HeraeusQ 3949 Z1HPM 20
SDLMP 3000 T8/6J
PhilipsHPM 20
Kuehnast21300

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 4120 · 240 mmUshio MHL 4000/U2 · 241 mmTheimer TR 3500 A · 245 mmTheimer TR 2060 · 245 mmUshio MHL-5020 · 247 mmUshio MHL-5020S · 247 mmTheimer TH 5020 · 249 mmUshio MHL 4001 · 230 mm

Frequently asked

Which part numbers are listed for the same lamp as the Amergraph MP3000T8/6J?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 10 part numbers: Amergraph MP3000T8/6J, Theimer TR 3900, Sylvania MP 3000 T8, Ushio MHL 3000/2, BLV MHL 3000/2, Heraeus Q 3949 Z1HPM 20, SDL MP 3000 T8/6J, Philips HPM 20, Kuehnast 21300, Theimer TH 3900. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Amergraph MP3000T8/6J?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.