KILOWATTLAMPS
Home › UV exposure lamps › Ushio MHL 4001

Ushio MHL 4001 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 230 mm, gallium-doped (Ga). Also listed as Theimer TR 4000, Heraeus 45006054 and 17 more part numbers.

Power5,000 W
DopingGallium-doped (Ga)
Overall length (mm)230 (US distributor catalogue)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 4001?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 4001
TheimerTR 4000 · TH 4000
Heraeus45006054 · Q 5526 Z1 · 56001209 · Q 5527 Z1
StaubUltralux 5 · PC 130 · HS 5000
SixtSL 5 KW/3340 · HL 5000
SylvaniaMO 92 · MO 23 · MO 17
BLVMHL 4001
AmbaAM 604 X
Kalle892
Sack200 615 · 200 215 UL

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 2090 · 230 mmTheimer TR 3950 A · 228 mmTheimer TR 4220 · 227 mmTechnigraf MA030 AC0195 · 225 mmTheimer TR 4120 · 240 mmAmergraph MP3000T8/6J · 240 mmTheimer TR 5080 · 220 mmUshio MHL 4000/U2 · 241 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 4001?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 20 part numbers: Ushio MHL 4001, Theimer TR 4000, Heraeus 45006054, Heraeus Q 5526 Z1, Heraeus 56001209, Staub Ultralux 5, Sixt SL 5 KW/3340, Heraeus Q 5527 Z1, Staub PC 130, Sylvania MO 92, Sylvania MO 23, Sylvania MO 17, BLV MHL 4001, Staub HS 5000, Sixt HL 5000, Amba AM 604 X, Kalle 892, Sack 200 615, Sack 200 215 UL, Theimer TH 4000. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 4001?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote