Theimer TR 5080 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 220 mm, gallium-doped (Ga). Also listed as Theimer TH 5080, Philips HPM 16 and 15 more part numbers.

Power2,000 W (published figures differ between sources — confirm on the label)
DopingGallium-doped (Ga)
Overall length (mm)220 (US distributor catalogue)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TR 5080?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTR 5080 · TH 5080
PhilipsHPM 16
HeraeusQ 5337 Z1 · AM 698 X · AM 618 X
BeltronMH 2000 W · 28075 · MH 7000 Typ 2 · 5000-28055 · 3000 E · 3000 W · 28053 · 28052 · 28026 · 28016
AmbaAM 698 X · AM 618 X

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 5100 · 215 mmUshio MHL-38KT · 215 mmTechnigraf MA030 AC0195 · 225 mmTheimer TR 4220 · 227 mmTheimer TR 3950 A · 228 mmUshio MHL 4001 · 230 mmUshio MHL 6020 S · 210 mmTheimer TR 2090 · 230 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TR 5080?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 18 part numbers: Theimer TR 5080, Theimer TH 5080, Philips HPM 16, Heraeus Q 5337 Z1, Beltron MH 2000 W, Beltron 28075, Beltron MH 7000 Typ 2, Beltron 5000-28055, Beltron 3000 E, Beltron 3000 W, Beltron 28053, Beltron 28052, Beltron 28026, Heraeus AM 698 X, Heraeus AM 618 X, Amba AM 698 X, Amba AM 618 X, Beltron 28016. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TR 5080?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote