KILOWATTLAMPS
Home › UV exposure lamps › Theimer TR 5100

Theimer TR 5100 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 215 mm, gallium-doped (Ga). Also listed as Theimer TH 5100, Sylvania MO 74 and 3 more part numbers.

Power6,000 W
DopingGallium-doped (Ga)
Overall length (mm)215 (US distributor catalogue)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TR 5100?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTR 5100 · TH 5100
SylvaniaMO 74
SixtSL 6 KW · SL 3345 A
KuehnastJGMH 4031-0

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL-38KT · 215 mmUshio MHL 6020 S · 210 mmTheimer TR 5080 · 220 mmOlec L 1150 B · 210 mmTheimer TR 4080 A · 205 mmTechnigraf MA030 AC0195 · 225 mmTheimer TR 4220 · 227 mmTheimer TR 3950 A · 228 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TR 5100?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 6 part numbers: Theimer TR 5100, Theimer TH 5100, Sylvania MO 74, Sixt SL 6 KW, Sixt SL 3345 A, Kuehnast JGMH 4031-0. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TR 5100?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote