KILOWATTLAMPS
Home › UV exposure lamps › Olec L 1150 B

Olec L 1150 B — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 210 mm, gallium-doped (Ga). Also listed as Theimer TR 2180, Fabcon L 1150 B and 1 more part numbers.

PowerNot published — read it from the lamp label
DopingGallium-doped (Ga)
Overall length (mm)210 (US distributor catalogue)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Olec L 1150 B?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
OlecL 1150 B
TheimerTR 2180 · TH 2180
FabconL 1150 B

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL 6020 S · 210 mmTheimer TR 5100 · 215 mmUshio MHL-38KT · 215 mmTheimer TR 4080 A · 205 mmNuArc KT 19 · 202 mmTheimer TR 4010 · 200 mmTheimer TR 5080 · 220 mmTheimer TR 2130 · 200 mm

Frequently asked

Which part numbers are listed for the same lamp as the Olec L 1150 B?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 4 part numbers: Olec L 1150 B, Theimer TR 2180, Fabcon L 1150 B, Theimer TH 2180. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Olec L 1150 B?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote