KILOWATTLAMPS
Home › UV exposure lamps › ORC MXA-7000H

ORC MXA-7000H — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 388 mm, gallium-doped (Ga). Also listed as Alpha Cure AC-0567, Theimer TR 7010 and 8 more part numbers.

PowerNot published — read it from the lamp label
DopingGallium-doped (Ga)
Overall length (mm)388 (US distributor catalogue)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the ORC MXA-7000H?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
ORCMXA-7000H
Alpha CureAC-0567
TheimerTR 7010 · TH 7010
Superior QuartzSQP-MXA7000HRC
BeltronMH 7000 E
BLV25540701 · MHL 7000
UshioMHL 7000
AmbaAM 426 X · AM 5636 X

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Technigraf MH 7500 S · 369 mmUshio GL 60201 BF · 350 mmTheimer TR 5110 · 305 mmUshio MHL 5000 SP · 295 mmTheimer TR 5140 · 281 mmUshio MHL-5000/4 · 280 mmTheimer TRHO 5590 · 280 mmTechnigraf UK 936 · 280 mm

Frequently asked

Which part numbers are listed for the same lamp as the ORC MXA-7000H?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 11 part numbers: ORC MXA-7000H, Alpha Cure AC-0567, Theimer TR 7010, Superior Quartz SQP-MXA7000HRC, Beltron MH 7000 E, BLV 25540701, Ushio MHL 7000, BLV MHL 7000, Amba AM 426 X, Amba AM 5636 X, Theimer TH 7010. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the ORC MXA-7000H?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote