KILOWATTLAMPS
Home › UV exposure lamps › Theimer TH 5007

Theimer TH 5007 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 191 mm, iron-doped (Fe). Also listed as Sack 200 215 OZ, Primarc 56070313 and 6 more part numbers.

Power3,880 W
DopingIron-doped (Fe)
Overall length (mm)191 (US distributor catalogue); 190mm (Alpha-Cure Theimer TH5007); 180mm (Alpha-Cure Parker HPM3000)
Arc / lighted length (mm)94mm (Alpha-Cure Theimer TH5007); 80mm (Alpha-Cure Parker HPM3000)
Tube diameter (mm)28mm (Alpha-Cure Theimer TH5007); 28mm (Alpha-Cure Parker HPM3000)
Base / connectionPinch seal (Alpha-Cure Theimer TH5007); Pinch seal (Alpha-Cure Parker HPM3000)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TH 5007?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTH 5007
Sack200 215 OZ
Primarc56070313
KuehnastJGMH 5000-7
SylvaniaM025
AmbaAM612X
HeraeusRQ 4128 Z4 KC
PhilipsHPM 3000
Dr. FischerHPM 3000

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 3027 · 190 mmTheimer TR 2517 · 190 mmTheimer TR 3117 · 190 mmTheimer TR 5047 · 190 mmUshio MHL 3027 S · 190 mmTheimer TR 5007 · 186 mmNuArc R 6074 · 178 mmUshio MHL 1403 · 175 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TH 5007?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 9 part numbers: Theimer TH 5007, Sack 200 215 OZ, Primarc 56070313, Kuehnast JGMH 5000-7, Sylvania M025, Amba AM612X, Heraeus RQ 4128 Z4 KC, Philips HPM 3000, Dr. Fischer HPM 3000. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TH 5007?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote