Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 190 mm, iron-doped (Fe). Also listed as Heraeus 45002210, Heraeus 45006071 and 9 more part numbers.

Power2,830 W
DopingIron-doped (Fe)
Overall length (mm)190 (US distributor catalogue); 190mm (Alpha-Cure Theimer THS3027)
Arc / lighted length (mm)94mm (Alpha-Cure Theimer THS3027)
Tube diameter (mm)24mm (Alpha-Cure Theimer THS3027)
Base / connectionPinch seal (Alpha-Cure Theimer THS3027)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 3027 S?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 3027 S
Heraeus45002210 · 45006071 · RQ 3146 Z4 KC · RQ 3147 Z4 KC
Cure UV191159
Theimer821397 · TRS 3027 · THS 3027
BLVMHL 3027 S
Kuehnast3020-7S
AmbaAM 603 XS

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 3027 · 190 mmTheimer TR 2517 · 190 mmTheimer TR 3117 · 190 mmTheimer TR 5047 · 190 mmTheimer TH 5007 · 191 mmTheimer TR 5007 · 186 mmNuArc R 6074 · 178 mmUshio MHL 1403 · 175 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 3027 S?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 12 part numbers: Ushio MHL 3027 S, Heraeus 45002210, Heraeus 45006071, Heraeus RQ 3146 Z4 KC, Cure UV 191159, Theimer 821397, Theimer TRS 3027, BLV MHL 3027 S, Kuehnast 3020-7S, Heraeus RQ 3147 Z4 KC, Amba AM 603 XS, Theimer THS 3027. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 3027 S?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote