Home › UV exposure lamps › Theimer TR 5007

Theimer TR 5007 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 186 mm, iron-doped (Fe). Also listed as Theimer TH 5007, Interlight WW-5E2G-9 and 7 more part numbers.

Power5,000 W (published figures differ between sources — confirm on the label)
DopingIron-doped (Fe)
Overall length (mm)186 (US distributor catalogue); 190mm (Alpha-Cure Horizon 200415); 190mm (Alpha-Cure Theimer TH5007)
Arc / lighted length (mm)94mm (Alpha-Cure Horizon 200415); 94mm (Alpha-Cure Theimer TH5007)
Tube diameter (mm)28mm (Alpha-Cure Horizon 200415); 28mm (Alpha-Cure Theimer TH5007)
Base / connectionPinch seal (Alpha-Cure Horizon 200415); Pinch seal (Alpha-Cure Theimer TH5007)
Doping / spectrumFe (iron-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TR 5007?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTR 5007 · TH 5007
InterlightWW-5E2G-9
SylvaniaMO 57
Sack200 415
PhilipsHPA 3000R
Klimsch659 7400 · 5000 W HF
HeraeusQ 4128 Z4
AmbaAM 612 X

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 3027 · 190 mmTheimer TR 2517 · 190 mmTheimer TR 3117 · 190 mmTheimer TR 5047 · 190 mmUshio MHL 3027 S · 190 mmTheimer TH 5007 · 191 mmNuArc R 6074 · 178 mmUshio MHL 1403 · 175 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TR 5007?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 10 part numbers: Theimer TR 5007, Theimer TH 5007, Interlight WW-5E2G-9, Sylvania MO 57, Sack 200 415, Philips HPA 3000R, Klimsch 659 7400, Klimsch 5000 W HF, Heraeus Q 4128 Z4, Amba AM 612 X. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TR 5007?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.