KILOWATTLAMPS
Home › UV exposure lamps › Theimer TRO 3030 HJ

Theimer TRO 3030 HJ — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 270 mm, gallium-doped (Ga). Also listed as Theimer THO 3030 HJ, Amba AM 7805 X.

Power3,010 W
DopingGallium-doped (Ga)
Overall length (mm)270 (US distributor catalogue); 270mm (Alpha-Cure Amba AM7805X)
Arc / lighted length (mm)150mm (Alpha-Cure Amba AM7805X)
Tube diameter (mm)20mm (Alpha-Cure Amba AM7805X)
Base / connectionRoll seal (Alpha-Cure Amba AM7805X)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TRO 3030 HJ?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTRO 3030 HJ · THO 3030 HJ
AmbaAM 7805 X

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio LB1113 GL-3kW · 270 mmTheimer TR 3250 H · 273 mmTechnigraf BTO4030 · 265 mmUshio MHL-5000/4 · 280 mmTheimer TRHO 5590 · 280 mmTechnigraf UK 936 · 280 mmTheimer TR 4090 B · 280 mmTheimer TRO 4090 · 280 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TRO 3030 HJ?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 3 part numbers: Theimer TRO 3030 HJ, Theimer THO 3030 HJ, Amba AM 7805 X. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TRO 3030 HJ?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote