Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 185 mm, gallium-doped (Ga). Also listed as Heraeus 45000799, Heraeus 45006057 and 22 more part numbers.
Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.
The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.
| Brand | Part number(s) |
|---|---|
| Ushio | MHL 5000 |
| Heraeus | 45000799 · 45006057 · Q 4128 Z1 · RQ 4127 Z1 KC |
| Theimer | TR 5000 · TH 5000 |
| Sylvania | MO 42 · MO 28.3 · MO 26 |
| Staub | Ultralux 5000 |
| Sixt | 5002 |
| Sack | 200 215 |
| Philips | HPM 3000 |
| Klimsch | 659 7340 · 5000 W OL |
| Degra | 85393290 |
| BLV | MHL 5000 |
| Bacher | 56066650 · 56033083 · 3081 |
| Amba | AM 689 X · AM 610 X |
| Aktilux | AL 5000 · AKT 6200 |
Shown for navigation only — a lamp only fits if length, base and doping all match your unit.
In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 25 part numbers: Ushio MHL 5000, Heraeus 45000799, Heraeus 45006057, Theimer TR 5000, Sylvania MO 42, Sylvania MO 28.3, Sylvania MO 26, Staub Ultralux 5000, Sixt 5002, Sack 200 215, Philips HPM 3000, Klimsch 659 7340, Klimsch 5000 W OL, Heraeus Q 4128 Z1, Heraeus RQ 4127 Z1 KC, Degra 85393290, BLV MHL 5000, Bacher 56066650, Bacher 56033083, Bacher 3081, Amba AM 689 X, Amba AM 610 X, Aktilux AL 5000, Aktilux AKT 6200, Theimer TH 5000. Confirm the length, base and doping of the lamp in your unit before ordering.
Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.
The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.
Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.