KILOWATTLAMPS
Home › UV exposure lamps › Ushio MHL 5000 S

Ushio MHL 5000 S — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 185 mm, gallium-doped (Ga). Also listed as Ushio 25520303, Heraeus 45002211 and 13 more part numbers.

Power3,780 W
DopingGallium-doped (Ga)
Overall length (mm)185 (US distributor catalogue); 185mm (Alpha-Cure BLV MHL5000S)
Arc / lighted length (mm)95mm (Alpha-Cure BLV MHL5000S)
Tube diameter (mm)28mm (Alpha-Cure BLV MHL5000S)
Base / connectionPinch seal (Alpha-Cure BLV MHL5000S)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 5000 S?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 5000 S · 25520303
Heraeus45002211 · 45006072 · RQ 4131 Z1 KC · RQ 4129 Z1 KC
Theimer820590 · TRS 5000 · THS 5000
PhilipsHPM 3008
BLVMHL 5000 S · 25520303
StarnaSTR 50000
SylvaniaMO 26.2
Kuehnast5000-0S
AmbaAM 611 XS

Equipment this lamp is listed for

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Ushio MHL 5000 · 185 mmTheimer TR 5230 · 185 mmUshio MHL-121 HT · 181 mmUshio MHL 17 · 190 mmTheimer TR 3020 · 190 mmNuArc HT 121 GA · 180 mmAmergraph HID 10266 A · 180 mmUshio MHL 2000/1 · 178 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 5000 S?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 16 part numbers: Ushio MHL 5000 S, Ushio 25520303, Heraeus 45002211, Heraeus 45006072, Heraeus RQ 4131 Z1 KC, Theimer 820590, Theimer TRS 5000, Philips HPM 3008, BLV MHL 5000 S, BLV 25520303, Heraeus RQ 4129 Z1 KC, Theimer THS 5000, Starna STR 50000, Sylvania MO 26.2, Kuehnast 5000-0S, Amba AM 611 XS. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 5000 S?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote