KILOWATTLAMPS
Home › UV exposure lamps › Ushio MHL 2000/1

Ushio MHL 2000/1 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 178 mm, gallium-doped (Ga). Also listed as Ushio 25341241, Ushio 5000084 and 10 more part numbers.

Power2,040 W
DopingGallium-doped (Ga)
Overall length (mm)178 (US distributor catalogue); 178mm (Alpha-Cure Theimer HT28); 178mm (Alpha-Cure Theimer TH2200)
Arc / lighted length (mm)82mm (Alpha-Cure Theimer HT28); 82mm (Alpha-Cure Theimer TH2200)
Tube diameter (mm)24mm (Alpha-Cure Theimer HT28); 24mm (Alpha-Cure Theimer TH2200)
Base / connectionPinch seal (Alpha-Cure Theimer HT28); Pinch seal (Alpha-Cure Theimer TH2200)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 2000/1?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 2000/1 · 25341241 · 5000084
M&RHT28
BLV25341241 · 5000084 · MHL 2000/1
TheimerTR 2200 · TH 2200
Cure UV191152
NuArcHT 28
GEPAGA 2000-1
AmbaAM 520 X

Equipment this lamp is listed for

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

NuArc HT 121 GA · 180 mmAmergraph HID 10266 A · 180 mmUshio MHL 17 · 175 mmUshio MHL-121 HT · 181 mmAmergraph 10048 GA · 175 mmUshio MHL 5000 · 185 mmTheimer TR 5230 · 185 mmUshio MHL 5000 S · 185 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 2000/1?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 13 part numbers: Ushio MHL 2000/1, Ushio 25341241, Ushio 5000084, M&R HT28, BLV 25341241, BLV 5000084, Theimer TR 2200, Cure UV 191152, BLV MHL 2000/1, Theimer TH 2200, NuArc HT 28, GE PAGA 2000-1, Amba AM 520 X. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 2000/1?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.