Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 175 mm, gallium-doped (Ga). Also listed as Beltron 28052, Kuehnast JGMHO 2200-0 and 6 more part numbers.

Power3,980 W
DopingGallium-doped (Ga)
Overall length (mm)175 (US distributor catalogue); 189mm (Alpha-Cure Theimer TH2510); 189mm (Alpha-Cure Amba AM572X)
Arc / lighted length (mm)101mm (Alpha-Cure Theimer TH2510); 101mm (Alpha-Cure Amba AM572X)
Tube diameter (mm)28mm (Alpha-Cure Theimer TH2510); 28mm (Alpha-Cure Amba AM572X)
Base / connectionPinch seal (Alpha-Cure Theimer TH2510); Pinch seal (Alpha-Cure Amba AM572X)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Ushio MHL 17?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
UshioMHL 17
Beltron28052
KuehnastJGMHO 2200-0
SylvaniaM036
TheimerTH 2510
AmbaAM572X
HeraeusQ 2123 Z11
PhilipsHPM 17
Dr. FischerHPM 17

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Amergraph 10048 GA · 175 mmUshio MHL 2000/1 · 178 mmNuArc HT 121 GA · 180 mmAmergraph HID 10266 A · 180 mmUshio MHL-121 HT · 181 mmUshio MHL 5000 · 185 mmTheimer TR 5230 · 185 mmUshio MHL 5000 S · 185 mm

Frequently asked

Which part numbers are listed for the same lamp as the Ushio MHL 17?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 9 part numbers: Ushio MHL 17, Beltron 28052, Kuehnast JGMHO 2200-0, Sylvania M036, Theimer TH 2510, Amba AM572X, Heraeus Q 2123 Z11, Philips HPM 17, Dr. Fischer HPM 17. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Ushio MHL 17?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.