Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 132 mm, gallium-doped (Ga). Also listed as Theimer TH 3000, Waldhauser 3000 W and 26 more part numbers.
Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.
The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.
| Brand | Part number(s) |
|---|---|
| Theimer | TR 3000 · TH 3000 |
| Waldhauser | 3000 W |
| Technigraf | 6303301 |
| Sylvania | MO 25 |
| Sack | 200 213 |
| Philips | HPM 2010 |
| Klimsch | 659 7320 · 3000 W OL |
| Heraeus | 45002002 · RQ 2128 Z1 · 45006050 · RQ 2129 Z1 |
| Helioprint | 2000 W |
| Heitmann | Heima Top |
| DuPont | 8000912 |
| Degra | 3000 W |
| BLV | MHL 3001 |
| Bacher | MH 3000 Z1 · 56066585 · 56066111 · 56001342 · 3031205 · Repro 2000 |
| Amba | AM 595 X · AM 505 X |
| Alpha Cure | AC 00751 |
| Aktilux | AL 3000-33 · AKT 3201 |
Shown for navigation only — a lamp only fits if length, base and doping all match your unit.
In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 29 part numbers: Theimer TR 3000, Theimer TH 3000, Waldhauser 3000 W, Technigraf 6303301, Sylvania MO 25, Sack 200 213, Philips HPM 2010, Klimsch 659 7320, Klimsch 3000 W OL, Heraeus 45002002, Heraeus RQ 2128 Z1, Heraeus 45006050, Heraeus RQ 2129 Z1, Helioprint 2000 W, Heitmann Heima Top, DuPont 8000912, Degra 3000 W, BLV MHL 3001, Bacher MH 3000 Z1, Bacher 56066585, Bacher 56066111, Bacher 56001342, Bacher 3031205, Amba AM 595 X, Amba AM 505 X, Alpha Cure AC 00751, Aktilux AL 3000-33, Aktilux AKT 3201, Bacher Repro 2000. Confirm the length, base and doping of the lamp in your unit before ordering.
Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.
The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.
Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.