KILOWATTLAMPS
Home › UV exposure lamps › Theimer TRS 3000

Theimer TRS 3000 — UV exposure lamp replacement

Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 132 mm, gallium-doped (Ga). Also listed as Theimer 820390, Theimer THS 3000 and 10 more part numbers.

Power3,000 W (published figures differ between sources — confirm on the label)
DopingGallium-doped (Ga)
Overall length (mm)132 (US distributor catalogue); 132mm (Alpha-Cure Theimer THS3000)
Arc / lighted length (mm)46mm (Alpha-Cure Theimer THS3000)
Tube diameter (mm)28mm (Alpha-Cure Theimer THS3000)
Base / connectionPinch seal (Alpha-Cure Theimer THS3000)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TRS 3000?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTRS 3000 · 820390 · THS 3000
Heraeus45002207 · RQ 2120 Z1 KC · 45006068 · RQ 2121 Z1 KC
PhilipsHPM 2018 · HPA 2018
Dialux3000
SackTDS-HSS 3000 W
SylvaniaMO 25.2
AmbaAM 596 XS

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 3000 · 132 mmTheimer TRS 2110 · 132 mmTheimer TRS 4020 · 145 mmUshio MHL 17 · 175 mmAmergraph 10048 GA · 175 mmUshio MHL 2000/1 · 178 mmNuArc HT 121 GA · 180 mmAmergraph HID 10266 A · 180 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TRS 3000?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 13 part numbers: Theimer TRS 3000, Theimer 820390, Theimer THS 3000, Heraeus 45002207, Heraeus RQ 2120 Z1 KC, Heraeus 45006068, Philips HPM 2018, Heraeus RQ 2121 Z1 KC, Dialux 3000, Sack TDS-HSS 3000 W, Sylvania MO 25.2, Philips HPA 2018, Amba AM 596 XS. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TRS 3000?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote