Metal-halide (long-arc) lamp for PCB, screen-printing and plate exposure units, 132 mm, gallium-doped (Ga). Also listed as Theimer THS 2110, Theimer 828290 and 1 more part numbers.

Power1,990 W
DopingGallium-doped (Ga)
Overall length (mm)132 (US distributor catalogue); 132mm (Alpha-Cure Theimer THS2110)
Arc / lighted length (mm)42mm (Alpha-Cure Theimer THS2110)
Tube diameter (mm)28mm (Alpha-Cure Theimer THS2110)
Base / connectionPinch seal (Alpha-Cure Theimer THS2110)
Doping / spectrumGa (gallium-doped)
Rated life (h)600 (US distributor catalogue typical/warranty)

Need a replacement for the Theimer TRS 2110?

Send the part number, a photo of the old lamp and your exposure unit model. We check length, base, doping and power and quote within 24 hours.

Quote form

Part numbers listed for this lamp

The same lamp — same overall length and spectrum — appears under all of these numbers in published replacement-lamp catalogues. Brand names identify the original part only.

BrandPart number(s)
TheimerTRS 2110 · THS 2110 · 828290
AmbaAM 590 XS

Other exposure lamps with the same doping and similar length

Shown for navigation only — a lamp only fits if length, base and doping all match your unit.

Theimer TR 3000 · 132 mmTheimer TRS 3000 · 132 mmTheimer TRS 4020 · 145 mmUshio MHL 17 · 175 mmAmergraph 10048 GA · 175 mmUshio MHL 2000/1 · 178 mmNuArc HT 121 GA · 180 mmAmergraph HID 10266 A · 180 mm

Frequently asked

Which part numbers are listed for the same lamp as the Theimer TRS 2110?

In published replacement-lamp catalogues the same lamp (same overall length and spectrum) is listed under 4 part numbers: Theimer TRS 2110, Theimer THS 2110, Theimer 828290, Amba AM 590 XS. Confirm the length, base and doping of the lamp in your unit before ordering.

Can you supply a replacement for the Theimer TRS 2110?

Yes — send the part number on your old lamp, a photo of its label and ends, and your exposure unit model. We check overall length, base, doping and power against the original before we quote, and quote within 24 hours.

Why does the doping matter?

The metal added to the mercury fill (iron, gallium or none) sets which UV and violet wavelengths the lamp emits. Your dry film, solder mask, screen emulsion or printing plate is sensitised to particular wavelengths, so the replacement should carry the same doping as the original.

Safety: metal-halide exposure lamps contain mercury and emit strong UV. Never run one outside its housing, wear UV-blocking eye protection when servicing, handle with gloves, and return used lamps for mercury recycling.

Specifications and cross-references compiled from published lamp-maker data (Ushio, Alpha-Cure) and a US replacement-lamp distributor's catalogue. Where sources differ the values are shown side by side. Data is given for identification only — verify against your unit's manual. Lamps supplied by Kilowatt Lamps are compatible replacements and are not made by or affiliated with the brands named.

WhatsApp quote